linux nginx+keepalived实现双机热切的高可用

Nginx+keepalived热切换高可用

一?keepalived简介

keepalived是一个类似于layer3,?4?&?7交换机制的软件,也就是我们平时说的第3层、第4层和第7层交换。

Keepalived的作用是检测web服务器的状态,如果有一台web服务器死机,或工作出现故障,Keepalived将检测到,并将有故障的web服务器从系统中剔除,当web服务器工作正常后Keepalived自动将web服务器加入到服务器群中,这些工作全部自动完成,不需要人工干涉,需要人工做的只是修复故障的web服务器。

为了方便测试清关闭防火墙?service?iptables?stop

二?安装

1,本次采用的是centos5.10?两台机器?(master_slave)架构master?192.168.235.101,

slave?192.168.235.102

2,准备编译环境?yum?-y?install?gcc?gcc+?gcc-c++?openssl?openssl-devel?pcre?pcre-devel

3,下载软件源代码包

Nginx1.7.0?最新版

wget??http://nginx.org/download/nginx-1.7.0.tar.gz

keepalived?1.2.12最新版

wget??http://www.keepalived.org/software/keepalived-1.2.12.tar.gz

4,编译安装源代码

a.?Nginx的安装(两台机器进行相同的安装即可)

解压nginx

tar?xf?nginx-1.7.0

cd?nginx1.7.0

./configure

make?&&?make?install

如果没有报错证明安装成功

测试

/usr/local/nginx/sbin/nginx?–t

[root@keepMaster?opt]#?/usr/local/nginx/sbin/nginx?-t

nginx:?the?configuration?file?/usr/local/nginx/conf/nginx.conf?syntax?is?ok

nginx:?configuration?file?/usr/local/nginx/conf/nginx.conf?test?is?successful

表示成功

b.?keepalived安装

tar?xf?keepalived-1.2.12.tar.gz

cd?keepalived-1.2.12

./configure

make?&&?make?install

cp?/usr/local/etc/rc.d/init.d/keepalived?/etc/init.d/

cp?/usr/local/etc/sysconfig/keepalived?/etc/sysconfig/

chmod?+x?/etc/init.d/keepalived

chkconfig?–add?keepalived

chkconfig?keepalived?on

mkdir?/etc/keepalived

ln?–s?/usr/local/sbin/keepalived?/usr/sbin

三?配置

Keepalived的配置

a在master机器(192.168.235.101中的配置)

vi?/etc/keepalived/?keepalived.config?//这个文件默认是不存在的

使用vi?加入以下的配置

global_defs?{

notification_email?{

admin@centos.bz

}

notification_email_from?keepalived@domain.com

smtp_server?127.0.0.1

smtp_connect_timeout?30

router_id?LVS_DEVEL

}

vrrp_script?chk_http_port?{

script?”/opt/nginx_pid.sh”?############该脚本我们在后面书写

interval?2

weight?2

}

vrrp_instance?VI_1?{

state?MASTER????????############?辅机为?BACKUP

interface?eth0

virtual_router_id?51

mcast_src_ip?192.168.235.101

priority?102??????????????????###########?权值要比?back?高

advert_int?1

authentication?{

auth_type?PASS

auth_pass?1111

}

track_script?{

chk_http_port?###?执行监控的服务

}

virtual_ipaddress?{

192.168.235.100?############?此处的虚拟IP?地址即?我们web所??????????????????????????????????????????????????????####要访问的IP地址??必须在同一网段

}

}

b?配置slave(192.168.235.102)

vi?/etc/keepalived/?keepalived.config?//这个文件默认是不存在的

使用vi?加入以下的配置

global_defs?{

notification_email?{

admin@centos.bz

}

notification_email_from?keepalived@domain.com

smtp_server?127.0.0.1

smtp_connect_timeout?30

router_id?LVS_DEVEL

}

vrrp_script?chk_http_port?{

script?”/opt/nginx_pid.sh”?############该脚本我们在后####面书写

interval?2

weight?2

}

vrrp_instance?VI_1?{

state?BACKUP

interface?eth0

virtual_router_id?51

mcast_src_ip?192.168.235.102

priority?102??????????????????###########?权值要比?back?低

advert_int?1

authentication?{

auth_type?PASS

auth_pass?1111

}

track_script?{

chk_http_port?###?执行监控的服务

}

virtual_ipaddress?{

192.168.235.100?############?此处的虚拟IP?地址即?我们web所??????????????????????????????????????????????????????####要访问的IP地址??必须在同一网段

}

}

c?分别在master?slave上建立nginx的监控脚本文件

vi?/opt/nginx_pid.sh

输入以下配置

#!/bin/bash

A=`ps?–C?nginx?–no-header?|wc?-l`

if?[$A?–eq?0];then

/usr/local/nginx/sbin/nginx

sleep?3

if[`ps?–C?nginx?–no-header?|wc?-l`?-eq?0];then

killall?keepalived

fi

fi

四?测试

<!–[if !supportLists]–>1.?<!–[endif]–>分别在mster和slave上启动nginx??/usr/local/nginx/sbin/nginx

<!–[if !supportLists]–>2.?<!–[endif]–>先启动master(101)上的?keepalived??service?keepalived?start?再启动slave(102)

<!–[if !supportLists]–>3.?<!–[endif]–>在master上敲入?ip?a

2:?eth0:?<BROADCAST,MULTICAST,UP,LOWER_UP>?mtu?1500?qdisc?pfifo_fast?qlen?1000

link/ether?00:0c:29:c2:74:15?brd?ff:ff:ff:ff:ff:ff

inet?192.168.235.101/24?brd?192.168.235.255?scope?global?eth0

inet?192.168.235.110/32?scope?global?eth0?//虚拟IP成功了?使用该地址访问

inet6?fe80::20c:29ff:fec2:7415/64?scope?link

valid_lft?forever?preferred_lft?forever

此时在slave输入ip?a?是看不到虚拟ip的

<!–[if !supportLists]–>4.?<!–[endif]–>在master上关闭nginx??/usr/local/nginx/sbin/nginx?–s?stop?输入ip?a

2:?eth0:?<BROADCAST,MULTICAST,UP,LOWER_UP>?mtu?1500?qdisc?pfifo_fast?qlen?1000

link/ether?00:0c:29:c2:74:15?brd?ff:ff:ff:ff:ff:ff

inet?192.168.235.101/24?brd?192.168.235.255?scope?global?eth0

inet6?fe80::20c:29ff:fec2:7415/64?scope?link

valid_lft?forever?preferred_lft?forever

虚拟IP地址没有了

此时在slave下输入ip?a

看到inet?192.168.235.110/32?scope?global?eth0?说明成功了

下面是我测试机器

2:?eth0:?<BROADCAST,MULTICAST,UP,LOWER_UP>?mtu?1500?qdisc?pfifo_fast?qlen?1000

link/ether?00:0c:29:e3:a2:2b?brd?ff:ff:ff:ff:ff:ff

inet?192.168.235.102/24?brd?192.168.235.255?scope?global?eth0

inet?192.168.235.110/32?scope?global?eth0?//看到这个?表示切换成功?秒级别

inet6?fe80::20c:29ff:fee3:a22b/64?scope?link

valid_lft?forever?preferred_lft?forever

<!–[if !supportLists]–>5.?<!–[endif]–>重新启动master?上的nginx,keepalived会自动切换到master

<!–[if !supportLists]–>6.?<!–[endif]–>经测试在master意外断电的情况下任然不影响切换,并在master成功修复,重新启动成功之后,slave会自动切换到master

linux nginx+keepalived实现双机热切的高可用